Use of the Polar V800 and Actiheart 5 heart rate monitors for the assessment of heart rate variability (HRV) in horses

Mott, R. , Dowell, F. and Evans, N. (2021) Use of the Polar V800 and Actiheart 5 heart rate monitors for the assessment of heart rate variability (HRV) in horses. Applied Animal Behaviour Science, 241, 105401. (doi: 10.1016/j.applanim.2021.105401)

[img] Text
247163.pdf - Accepted Version
Available under License Creative Commons Attribution Non-commercial.

629kB
[img] Text
247163Suppl.pdf - Supplemental Material

284kB

Abstract

Heart rate variability (HRV) is a commonly used metric in animal science to quantify an aspect of the physiological response to stressors. HRV analysis relies upon accurate detection of the electrical activity of the heart to define inter-beat interval (IBI). In horses, this can be problematic due to specific features of the equine ECG waveform and a high incidence of 2nd-degree atrioventricular (AV) block in clinically normal horses at rest. The current study validates the collection and interpretation of IBI data from two heart rate monitors (HRMs) principally designed for human personal monitoring (Polar V800 and Actiheart 5). 30 min of synchronous IBI data was collected using the two HRMs and a 4-lead telemetric ECG that is widely used in equine veterinary clinical practice (Televet 100). The study was conducted using a mixed sample (n = 17) of general riding horses, with (n = 4) and without (n = 13) cardiac dysrhythmias. HRV data was derived from each IBI data set and compared following application of a series of correction factors. There was a very strong inter-class correlation of HRV parameters from both the Actiheart 5 and Polar V800 with the Televet 100 data. Both HRMs providing an acceptable level of agreement with both time and frequency domain HRV parameters. The data from the Actiheart 5 were found to be interchangeable with the Televet 100 in respect of beat detection whereas the Polar V800 data required a 0.4 s artefact correction to give best agreement. Both HRMs have utility in equine research for demonstrating the direction and magnitude of change in HRV parameters, although users must apply appropriate artefact correction to maximise data validity.

Item Type:Articles
Additional Information:The authors thank the Scottish SPCA and the University of Glasgow for financial support of this work.
Status:Published
Refereed:Yes
Glasgow Author(s) Enlighten ID:Dowell, Dr Fiona and Evans, Professor Neil and Mott, Richard
Authors: Mott, R., Dowell, F., and Evans, N.
College/School:College of Medical Veterinary and Life Sciences > School of Biodiversity, One Health & Veterinary Medicine
Journal Name:Applied Animal Behaviour Science
Publisher:Elsevier
ISSN:0168-1591
ISSN (Online):1872-9045
Published Online:19 July 2021
Copyright Holders:Copyright © 2021 Elsevier B.V.
First Published:First published in Applied Animal Behaviour Science 241: 105401
Publisher Policy:Reproduced in accordance with the publisher copyright policy

University Staff: Request a correction | Enlighten Editors: Update this record