Depth of interaction and bias voltage depenence of the spectral response in a pixellated CdTe detector operating in time-over-threshold mode subjected to monochromatic X-rays

Fröjdh, E. et al. (2012) Depth of interaction and bias voltage depenence of the spectral response in a pixellated CdTe detector operating in time-over-threshold mode subjected to monochromatic X-rays. Journal of Instrumentation, 7(3), C03002. (doi: 10.1088/1748-0221/7/03/C03002)

[img]
Preview
Text
99278.pdf - Published Version

502kB

Abstract

High stopping power is one of the most important figures of merit for X-ray detectors. CdTe is a promising material but suffers from: material defects, non-ideal charge transport and long range X-ray fluorescence. Those factors reduce the image quality and deteriorate spectral information. In this project we used a monochromatic pencil beam collimated through a 20μm pinhole to measure the detector spectral response in dependance on the depth of interaction. The sensor was a 1mm thick CdTe detector with a pixel pitch of 110μm, bump bonded to a Timepix readout chip operating in Time-Over-Threshold mode. The measurements were carried out at the Extreme Conditions beamline I15 of the Diamond Light Source. The beam was entering the sensor at an angle of \texttildelow20 degrees to the surface and then passed through \texttildelow25 pixels before leaving through the bottom of the sensor. The photon energy was tuned to 77keV giving a variation in the beam intensity of about three orders of magnitude along the beam path. Spectra in Time-over-Threshold (ToT) mode were recorded showing each individual interaction. The bias voltage was varied between -30V and -300V to investigate how the electric field affected the spectral information. For this setup it is worth noticing the large impact of fluorescence. At -300V the photo peak and escape peak are of similar height. For high bias voltages the spectra remains clear throughout the whole depth but for lower voltages as -50V, only the bottom part of the sensor carries spectral information. This is an effect of the low hole mobility and the longer range the electrons have to travel in a low field.

Item Type:Articles
Status:Published
Refereed:Yes
Glasgow Author(s) Enlighten ID:Stewart, Dr Graeme and O'Shea, Professor Val and Maneuski, Dr Dima
Authors: Fröjdh, E., Fröjdh, C., Gimenez, E.N., Maneuski, D., Marchal, J., Norlin, B., O'Shea, V., Stewart, G., Wilhelm, H., Zain, R.M., and Thungström, G.
College/School:College of Science and Engineering > School of Physics and Astronomy
Journal Name:Journal of Instrumentation
Publisher:Institute of Physics Publishing Ltd.
ISSN:1748-0221
ISSN (Online):1748-0221
Copyright Holders:Copyright © 2012 IOP Publishing Ltd and Sissa Medialab srl
First Published:First published in Journal of Instrumentation 7(3):C03002
Publisher Policy:Reproduced in accordance with the copyright policy of the publisher

University Staff: Request a correction | Enlighten Editors: Update this record