The design and performance of a scintillating-fibre tracker for the cosmic-ray muon tomography of legacy nuclear waste containers

Clarkson, A. et al. (2014) The design and performance of a scintillating-fibre tracker for the cosmic-ray muon tomography of legacy nuclear waste containers. Nuclear Instruments and Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment, 745, pp. 138-149. (doi: 10.1016/j.nima.2014.01.062)

Full text not currently available from Enlighten.

Publisher's URL: http://dx.doi.org/10.1016/j.nima.2014.01.062

Abstract

Tomographic imaging techniques using the Coulomb scattering of cosmic-ray muons are increasingly being exploited for the non-destructive assay of shielded containers in a wide range of applications. One such application is the characterisation of legacy nuclear waste materials stored within industrial containers. The design, assembly and performance of a prototype muon tomography system developed for this purpose are detailed in this work. This muon tracker comprises four detection modules, each containing orthogonal layers of Saint-Gobain BCF-10 2 mm-pitch plastic scintillating fibres. Identification of the two struck fibres per module allows the reconstruction of a space point, and subsequently, the incoming and Coulomb-scattered muon trajectories. These allow the container content, with respect to the atomic number Z of the scattering material, to be determined through reconstruction of the scattering location and magnitude. On each detection layer, the light emitted by the fibre is detected by a single Hamamatsu H8500 MAPMT with two fibres coupled to each pixel via dedicated pairing schemes developed to ensure the identification of the struck fibre. The PMT signals are read out to standard charge-to-digital converters and interpreted via custom data acquisition and analysis software. The design and assembly of the detector system are detailed and presented alongside results from performance studies with data collected after construction. These results reveal high stability during extended collection periods with detection efficiencies in the region of 80% per layer. Minor misalignments of millimetre order have been identified and corrected in software. A first image reconstructed from a test configuration of materials has been obtained using software based on the Maximum Likelihood Expectation Maximisation algorithm. The results highlight the high spatial resolution provided by the detector system. Clear discrimination between the low, medium and high-Z materials assayed is also observed.

Item Type:Articles
Status:Published
Refereed:Yes
Glasgow Author(s) Enlighten ID:Mahon, Dr David and Murray, Dr Morgan and Yang, Dr Guangliang and Hoek, Mr Matthias and Shearer, Dr Craig and Keri, Dr Tibor and McKinnon, Dr Bryan and Clarkson, Mr Anthony and Kaiser, Professor Ralf and Nutbeam-Tuffs, Mrs Sian and Ireland, Professor David and Hamilton, Dr David
Authors: Clarkson, A., Hamilton, D.J., Hoek, M., Ireland, D.G., Johnstone, J.R., Kaiser, R., Keri, T., Lumsden, S., Mahon, D.F., McKinnon, B., Murray, M., Nutbeam-Tuffs, S., Shearer, C., Staines, C., Yang, G., and Zimmerman, C.
College/School:College of Science and Engineering > School of Physics and Astronomy
Journal Name:Nuclear Instruments and Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment
Publisher:Elsevier
ISSN:0168-9002
ISSN (Online):1872-9576

University Staff: Request a correction | Enlighten Editors: Update this record