Towards the re-verification of process tank calibrations

Howell, J. (2009) Towards the re-verification of process tank calibrations. Transactions of the Institute of Measurement and Control, 31(2), pp. 117-128. (doi: 10.1177/0142331207086813)

[img] Text
40505.pdf

201kB

Abstract

Re-verification is needed to ensure that the calibration (the relationship between measured level and measured volume) that is obtained during commissioning hasn’t changed over time. This can be achieved, in part, by metering in solution and correlating with marks identified a priori. Mark identification and correlation are discussed and possible error sources are outlined.

Item Type:Articles
Status:Published
Refereed:Yes
Glasgow Author(s) Enlighten ID:Howell, Dr John
Authors: Howell, J.
Subjects:T Technology > TJ Mechanical engineering and machinery
College/School:College of Science and Engineering > School of Engineering > Systems Power and Energy
Journal Name:Transactions of the Institute of Measurement and Control
Publisher:Sage
ISSN:0142-3312
ISSN (Online):1477-0369
Copyright Holders:Copyright © 2009 Sage
First Published:First published in Transactions of the Institute of Measurement and Control 31(2):117-128
Publisher Policy:Reproduced in accordance with the copyright policy of the publisher

University Staff: Request a correction | Enlighten Editors: Update this record