AC loss in REBCO coil windings wound with various cables: Effect of current distribution among the cable strands

Song, W. , Badcock, R. A., Long, N. J. and Jiang, Z. (2023) AC loss in REBCO coil windings wound with various cables: Effect of current distribution among the cable strands. IEEE Access, 11, pp. 102082-102091. (doi: 10.1109/ACCESS.2023.3315731)

[img] Text
306958.pdf - Published Version
Available under License Creative Commons Attribution.

1MB

Abstract

To construct large-scale superconducting devices, it is critical to enhance the current carrying capability of superconducting coils. One practical approach is to utilise assembled cables, composed of multiple strands, for the winding. There have only been a few investigations of the dependence of current distribution among the strands on the AC losses of the cables and coils wound with these cables. In this work, we studied three types of cables; i) 8/2 (eight 2 mm-wide strands) Roebel cable, 8/2 Roebel; ii) two parallel stacks (TPS) which have the same geometrical dimensions as the Roebel cable, 8/2 TPS; and iii) an equivalent four-conductor stack (ES) comprising four 4 mm-wide conductors, 4/4 ES. We proposed a new numerical approach that can achieve equal current sharing and free current sharing among the strands. We examined the loss behaviour of all three types of straight cables and two coil assemblies comprising two, and eight, stacks of double pancakes (DPCs) wound with these cables, respectively. 2D FEM analysis was carried out in COMSOL Multiphysics using the H - formulation. The stacks were modelled in parallel connection, with the same electric field applied to all strands, so that current is distributed between the conductors. Simulated transport AC loss results in the straight 8/2 Roebel cable, 8/2 TPS and 4/4 ES were compared with previously measured results as well as each other. The numerical AC loss results in two coil windings 2-DPC and 8-DPC wound with the 8/2 Roebel cables were compared with the results in coil windings wound with the 8/2 TPS and 4/4 ES. No transposition was introduced at the connection between double pancakes, in order that current can be shared among the strands in the 8/2 TPS and 4/4 ES. The results indicate that AC loss in the straight 8/2 TPS and 4/4 ES is larger than that in the 8/2 Roebel cable. Current is more concentrated in the outer strands for the straight 8/2 TPS and 4/4 ES than the 8/2 Roebel cable and causes greater AC loss than the 8/2 Roebel cable. The 8-DPC coil winding wound with the 8/2 Roebel cable has the smallest loss and the coil winding wound with the 8/2 TPS has the greatest loss at two current amplitudes investigated. At 113 A, the AC loss value in the 8-DPC coil winding wound with the 8/2 TPS is 2.2 times of that wound with the 8/2 Roebel cable.

Item Type:Articles
Additional Information:The work was supported in part by the Start-up Fund from University of Glasgow, UK, and also supported in part by New Zealand Ministry of Business, Innovation and Employment (MBIE) by the Strategic Science Investment Fund ‘‘Advanced Energy Technology Platforms’’ under Contract RTVU2004.
Status:Published
Refereed:Yes
Glasgow Author(s) Enlighten ID:Song, Dr Wenjuan
Authors: Song, W., Badcock, R. A., Long, N. J., and Jiang, Z.
College/School:College of Science and Engineering > School of Engineering > Autonomous Systems and Connectivity
Journal Name:IEEE Access
Publisher:Institute of Electrical and Electronics Engineers
ISSN:2169-3536
ISSN (Online):2169-3536
Published Online:15 September 2023
Copyright Holders:Copyright © 2023 The Author(s)
First Published:First published in IEEE Access 11: 102082-102091
Publisher Policy:Reproduced under a Creative Commons license

University Staff: Request a correction | Enlighten Editors: Update this record