A cleaner and more efficient energy system achieving a sustainable future for road transport

Zhang, N., Lu, Y. and Yu, Z. (2023) A cleaner and more efficient energy system achieving a sustainable future for road transport. Journal of Cleaner Production, 418, 137982. (doi: 10.1016/j.jclepro.2023.137982)

[img] Text
303067.pdf - Published Version
Available under License Creative Commons Attribution.

3MB

Abstract

A novel integrated cooling system is developed for future medium to large electric vehicles by integrating the fuel cell, battery, metal-hydride, heat pump, and liquid desiccant dehumidification system to reduce power consumption and extend vehicle's driving range. The system benefits from the reuse of the normally wasted energy in the form of pressure difference and wasted thermal energy, from the hydrogen vessel, the fuel cell stack, and the battery pack. A numerical model for the proposed system and a finite element model for the dehumidifier and regenerator are developed and validated by experimental results from published data. A comprehensive evaluation of the impacts of the ambient air temperature and humidity, fuel cell current output, battery discharging C rate, and air mass flow rate on the Coefficient of Performance (COP), outlet air temperature, and cooling capacity is conducted. Two operating modes, namely non-compressive mode and heat pump supplemental mode are investigated and a detailed comparison between these two modes is undertaken. Furthermore, the proposed system under heat pump supplemental mode has been compared to other published cooling systems and dehumidification systems. Under non-compressive mode, results indicate that the proposed system can provide sufficient cooling capacity without the need of the compressor when the supply air mass flow rate is lower than 0.03kg/s, under the specific operating situation. Under the heat pump supplemental mode, the proposed system can operate at 36 °C with a COP greater than 4, which is 56% higher than the cited published results, although the COP of the proposed system also considers battery cooling. Heat pump supplemental mode drastically reduces the 12-second insufficient cooling period that occurs at the beginning of the charging to discharging transition between the two metal hydrides to 2 seconds compared to non-compressed mode. Overall, this study provides a potential solution for future zero-emission vehicles by utilizing the heat and electric co-generation characteristic of the fuel cell, the isothermal characteristic of the metal hydride, and dehumidification and cooling characteristics of the liquid desiccant dehumidification system to extend the driving range of the electric vehicles and reduce energy consumption for cooling. Moreover, the proposed system can also provide domestic cooling loads and power by integrating the system into residential buildings.

Item Type:Articles
Additional Information:The authors are very grateful for the generous support from EPSRC Decarbonization of Heating and Cooling (EP/T022701/1) and the ETP/Transport Scotland Industry Engagement Fund. This work was also funded by the University of Glasgow Studentship and China Scholarship Council (CSC) (202008230188).
Status:Published
Refereed:Yes
Glasgow Author(s) Enlighten ID:Zhang, Mr Nan and Yu, Professor Zhibin and Lu, Dr Yiji
Authors: Zhang, N., Lu, Y., and Yu, Z.
College/School:College of Science and Engineering > School of Engineering > Systems Power and Energy
Journal Name:Journal of Cleaner Production
Publisher:Elsevier
ISSN:0959-6526
ISSN (Online):1879-1786
Published Online:10 July 2023
Copyright Holders:Copyright © 2023 Crown Copyright
First Published:First published in Journal of Cleaner Production 418:137982
Publisher Policy:Reproduced under a Creative Commons License

University Staff: Request a correction | Enlighten Editors: Update this record