Programmatic evaluation of a combined antigen and antibody test for rapid HIV diagnosis in a community and sexual health clinic screening programme

Taegtmeyer, M., MacPherson, P. , Jones, K., Hopkins, M., Moorcroft, J., Lalloo, D. G. and Chawla, A. (2011) Programmatic evaluation of a combined antigen and antibody test for rapid HIV diagnosis in a community and sexual health clinic screening programme. PLoS ONE, 6(11), e28019. (doi: 10.1371/journal.pone.0028019) (PMID:22132195) (PMCID:PMC3222669)

[img] Text
301399.pdf - Published Version
Available under License Creative Commons Attribution.

282kB

Abstract

Background: A substantial proportion of HIV-infected individuals in the UK are unaware of their status and late presentations continue, especially in low prevalence areas. Fourth generation antigen/antibody rapid test kits could facilitate earlier diagnosis of HIV in non-clinical settings but lack data on performance under programmatic conditions. Methods and findings: We evaluated the performance of Determine HIV-1/2 Ag/Ab Combo Test (Determine Combo), a rapid test with indicators for both HIV antibodies and p24 antigen, in participants recruited from community outreach and hospital-based sexual health clinics. HIV infection was confirmed using laboratory enzyme-linked immunosorbent assay (EIA), Line Immuno Assay (LIA) and quantitative polymerase chain reaction (PCR). In total, 953 people underwent HIV testing. HIV antibody (Ab) prevalence was 1.8% (17/953). Four false positive rapid tests were identified: two antibody and two p24 antigen (Ag) reactions. Of participants diagnosed as HIV Ab positive, 2/17 (12%) were recent seroconverters based on clinical history and HIV antibody avidity test results. However, none of these were detected by the p24 antigen component of the rapid test kit. There were no other true positive p24 Ag tests. Conclusion: These data lend support to an increasing body of evidence suggesting that 4th generation rapid HIV tests have little additional benefit over 3rd generation HIV kits for routine screening in low prevalence settings and have high rates of false positives. In order to optimally combine community-based case-finding among hard-to-reach groups with reliable and early diagnosis 3rd generation kits should be primarily used with laboratory testing of individuals thought to be at risk of acute HIV infection. A more reliable point of care diagnostic is required for the accurate detection of acute HIV infection under programmatic conditions.

Item Type:Articles
Additional Information:This project was funded by the Gilead UK and Ireland Fellowship Programme 2009. Additionally 200 Determine test kits were donated by Inverness Medicine for use in the Liverpool Centre for Sexual Health.
Status:Published
Refereed:Yes
Glasgow Author(s) Enlighten ID:MacPherson, Professor Peter
Authors: Taegtmeyer, M., MacPherson, P., Jones, K., Hopkins, M., Moorcroft, J., Lalloo, D. G., and Chawla, A.
College/School:College of Medical Veterinary and Life Sciences > School of Health & Wellbeing > Public Health
Journal Name:PLoS ONE
Publisher:Public Library of Science
ISSN:1932-6203
ISSN (Online):1932-6203
Copyright Holders:Copyright © 2011 Taegtmeyer et al.
First Published:First published in PLoS ONE 6(11):e28019
Publisher Policy:Reproduced under a Creative Commons licence

University Staff: Request a correction | Enlighten Editors: Update this record