Calibration of patient-specific boundary conditions for coupled CFD models of the aorta derived from 4D Flow-MRI

Black, S. M., Maclean, C., Hall Barrientos, P., Ritos, K., McQueen, A. and Kazakidi, A. (2023) Calibration of patient-specific boundary conditions for coupled CFD models of the aorta derived from 4D Flow-MRI. Frontiers in Bioengineering and Biotechnology, 11, 1178483. (doi: 10.3389/fbioe.2023.1178483) (PMID:37251565) (PMCID:PMC10210162)

[img] Text
299380.pdf - Published Version
Available under License Creative Commons Attribution.

3MB

Abstract

Introduction: Patient-specific computational fluid dynamics (CFD) models permit analysis of complex intra-aortic hemodynamics in patients with aortic dissection (AD), where vessel morphology and disease severity are highly individualized. The simulated blood flow regime within these models is sensitive to the prescribed boundary conditions (BCs), so accurate BC selection is fundamental to achieve clinically relevant results. Methods: This study presents a novel reduced-order computational framework for the iterative flow-based calibration of 3-Element Windkessel Model (3EWM) parameters to generate patient-specific BCs. These parameters were calibrated using time-resolved flow information derived from retrospective four-dimensional flow magnetic resonance imaging (4D Flow-MRI). For a healthy and dissected case, blood flow was then investigated numerically in a fully coupled zero dimensional-three dimensional (0D-3D) numerical framework, where the vessel geometries were reconstructed from medical images. Calibration of the 3EWM parameters was automated and required ∼3.5 min per branch. Results: With prescription of the calibrated BCs, the computed near-wall hemodynamics (time-averaged wall shear stress, oscillatory shear index) and perfusion distribution were consistent with clinical measurements and previous literature, yielding physiologically relevant results. BC calibration was particularly important in the AD case, where the complex flow regime was captured only after BC calibration. Discussion: This calibration methodology can therefore be applied in clinical cases where branch flow rates are known, for example, via 4D Flow-MRI or ultrasound, to generate patient-specific BCs for CFD models. It is then possible to elucidate, on a case-by-case basis, the highly individualized hemodynamics which occur due to geometric variations in aortic pathology high spatiotemporal resolution through CFD.

Item Type:Articles
Additional Information:This work was supported in part by the UK Research and Innovation (UKRI) Engineering and Physical Sciences Research Council (EPSRC) Award Ref. EP/L015595/1 through the University of Strathclyde Centre of Doctoral Training and the European Union’s Horizon 2020 research and innovation programme under the Marie Sklodowska-Curie grant agreement No. 749185. AK was supported by the UKRI EPSRC Award Ref. EP/W004860/1 and EP/X033686/1 via the Transformative Healthcare Technologies scheme.
Keywords:Patient-specific, 4D Flow-MRI, Windkessel, calibration, boundary conditions, CFD, aortic dissection.
Status:Published
Refereed:Yes
Glasgow Author(s) Enlighten ID:McQueen, Mr Alistair and Hall Barrientos, Dr Pauline
Authors: Black, S. M., Maclean, C., Hall Barrientos, P., Ritos, K., McQueen, A., and Kazakidi, A.
College/School:College of Medical Veterinary and Life Sciences > School of Medicine, Dentistry & Nursing
College of Science and Engineering > School of Engineering
College of Science and Engineering > School of Engineering > Biomedical Engineering
Journal Name:Frontiers in Bioengineering and Biotechnology
Publisher:Frontiers Media
ISSN:2296-4185
ISSN (Online):2296-4185
Copyright Holders:Copyright © 2023 Black, Maclean, Hall Barrientos, Ritos, McQueen and Kazakidi
First Published:First published in Frontiers in Bioengineering and Biotechnology 11: 1178483
Publisher Policy:Reproduced under a Creative Commons License

University Staff: Request a correction | Enlighten Editors: Update this record