Application of laser spectroscopy for measurement of exhaled ethane in patients with lung cancer

Skeldon, K.D., McMillan, L.C., Wyse, C.A., Monk, S.D., Gibson, G. , Patterson, C., France, T., Longbottom, C. and Padgett, M.J. (2006) Application of laser spectroscopy for measurement of exhaled ethane in patients with lung cancer. Respiratory Medicine, 100(2), pp. 300-306. (doi: 10.1016/j.rmed.2005.05.006)

Full text not currently available from Enlighten.

Abstract

<p>There is increasing interest in ethane (C2H6) in exhaled breath as a non-invasive marker of oxidative stress (OS) and thereby a potential indicator of disease. However, the lack of real-time measurement techniques has limited progress in the field. Here we report on a novel Tunable Diode Laser Spectrometer (TDLS) applied to the analysis of exhaled ethane in patients with lung cancer. The patient group (n=52) comprised randomly selected patients presenting at a respiratory clinic. Of these, a sub-group (n=12) was subsequently diagnosed with lung cancer. An age-matched group (n=12) corresponding to the lung cancer group was taken from a larger control group of healthy adults (n=58). The concentration of ethane in a single exhaled breath sample collected from all subjects was later measured using the TDLS. This technique is capable of real-time analysis of samples with accuracy 0.1 parts per billion (ppb), over 10 times less than typical ambient levels in the northern hemisphere.</p> <p>After correcting for ambient background, ethane in the control group (26% smokers) ranged from 0 to 10.54 ppb (median of 1.9 ppb) while ethane in the lung cancer patients (42% smokers) ranged from 0 to 7.6 ppb (median of 0.7 ppb). Ethane among the non-lung cancer patients presenting for investigation of respiratory disease ranged from 0 to 25 ppb (median 1.45 ppb).</p> <p>We conclude that, while the TDLS proved effective for accurate and rapid sample analysis, there was no significant difference in exhaled ethane among any of the subject groups. Comments are made on the suitability of the technique for monitoring applications.</p>

Item Type:Articles
Status:Published
Refereed:Yes
Glasgow Author(s) Enlighten ID:Gibson, Dr Graham and Padgett, Professor Miles and Wyse, Dr Cathy and Skeldon, Dr Kenneth
Authors: Skeldon, K.D., McMillan, L.C., Wyse, C.A., Monk, S.D., Gibson, G., Patterson, C., France, T., Longbottom, C., and Padgett, M.J.
College/School:College of Science and Engineering > School of Physics and Astronomy
College of Medical Veterinary and Life Sciences > School of Biodiversity, One Health & Veterinary Medicine
Journal Name:Respiratory Medicine
Publisher:Elsevier Ltd
ISSN:0954-6111

University Staff: Request a correction | Enlighten Editors: Update this record