Wide Range-Sensitive, Bending-Insensitive Pressure Detection and Application to Wearable Healthcare Device

Kim, S., Amjadi, M. , Lee, T.-I., Jeong, Y., Kwon, D., Seong Kim, M., Kim, K., Kim, T.-S., Suk Oh, Y. and Park, I. (2019) Wide Range-Sensitive, Bending-Insensitive Pressure Detection and Application to Wearable Healthcare Device. In: 20th International Conference on Solid-State Sensors, Actuators and Microsystems & Eurosensors XXXIII (TRANSDUCERS & EUROSENSORS XXXIII), Berlin, Germany, 23-27 Jun 2019, pp. 374-377. ISBN 9781538681046 (doi: 10.1109/TRANSDUCERS.2019.8808529)

Full text not currently available from Enlighten.

Abstract

This paper reports a wide range-sensitive, bending-insensitive pressure sensor based on a carbon nanotube (CNT)-coated porous elastomer for a wearable healthcare application. (1) Sensing performance was evaluated over ~1MPa, which includes whole human tactile and body weight levels. The sensor exhibits a very wide sensing range from ultralow to high pressure (50Pa-1MPa) with maintenance of favorable sensitivity and reliable dynamic responses. (2) To our knowledge this is the first to investigate bending-insensitivity of the CNTs-coated porous PDMS, which facilitates accurate detection of normal pressures even on curved surfaces like human skins. (3) Finally, we demonstrated a foot insole for real-time monitoring of foot plantar pressure distribution.

Item Type:Conference Proceedings
Additional Information:Funding Information: This work was supported by the National Research Foundation of Korea (NRF) grant funded by the Korea government (MSIT) (No. 2018R1A2B2004910); (2) Basic Science Research Programs through the National Research Foundation (NRF) funded by the Korean government (No. 2015R1A5A1037668). Publisher Copyright: © 2019 IEEE.; 20th International Conference on Solid-State Sensors, Actuators and Microsystems and Eurosensors XXXIII ; Conference date: 23-06-2019 Through 27-06-2019
Keywords:Carbon Nanotube, Flexible Sensor, Porous Elastomer, Pressure Sensor
Status:Published
Refereed:Yes
Glasgow Author(s) Enlighten ID:Amjadi Kolour, Dr Morteza
Authors: Kim, S., Amjadi, M., Lee, T.-I., Jeong, Y., Kwon, D., Seong Kim, M., Kim, K., Kim, T.-S., Suk Oh, Y., and Park, I.
College/School:College of Science and Engineering > School of Engineering > Biomedical Engineering
Journal Name:20th International Conference on Solid-State Sensors, Actuators and Microsystems & Eurosensors XXXIII (TRANSDUCERS & EUROSENSORS XXXIII)
Publisher:IEEE
ISSN:2167-0021
ISBN:9781538681046

University Staff: Request a correction | Enlighten Editors: Update this record