A marking of the cricothyroid membrane with extended neck returns to correct position after neck manipulation and repositioning

Bowness, J., Teoh, W. H., Kristensen, M. S., Dalton, A., Le Saint-Grant, A., Taylor, A., Crawley, S., Chisholm, F., Varsou, O. and McGuire, B. (2020) A marking of the cricothyroid membrane with extended neck returns to correct position after neck manipulation and repositioning. Acta Anaesthesiologica Scandinavica, 64(10), 1422-142-1425. (doi: 10.1111/aas.13680) (PMID:32698252)

[img] Text
221258.pdf - Accepted Version

2MB

Abstract

Background: Emergency front of neck airway access by anaesthetists carries a high failure rate and it is recommended to identify the cricothyroid membrane before induction of anaesthesia in patients with a predicted difficult airway. We have investigated whether a marking of the cricothyroid membrane done in the extended neck position remains correct after the patient's neck has been manipulated and subsequently repositioned METHODS: The subject was first placed in the extended head and neck position and had the cricothyroid membrane identified and marked with three methods, palpation, 'laryngeal handshake' and ultrasonography and the distance from the suprasternal notch to the cricothyroid membrane was measured. The subject then moved off the table and sat on a chair and subsequently returned to the extended neck position and examinations were repeated. Results: Skin markings of all 11 subjects lay within the boundaries of the cricothyroid membrane when the subject was repositioned back to the extended neck position and the median difference between the two measurements of the distance from the suprasternal notch was 0 mm (range 0-2 mm). Conclusion: The cricothyroid membrane can be identified and marked with the subject in the extended neck position. Then the patient's position can be changed as needed, for example to the 'sniffing' neck position for conventional intubation. If a front of neck airway access is required during subsequent airway management, the patient can be returned expediently to the extended-neck position, and the marking of the centre of the membrane will still be in the correct place.

Item Type:Articles
Status:Published
Refereed:Yes
Glasgow Author(s) Enlighten ID:Varsou, Dr Ourania
Authors: Bowness, J., Teoh, W. H., Kristensen, M. S., Dalton, A., Le Saint-Grant, A., Taylor, A., Crawley, S., Chisholm, F., Varsou, O., and McGuire, B.
College/School:College of Medical Veterinary and Life Sciences > School of Life Sciences
Journal Name:Acta Anaesthesiologica Scandinavica
Journal Abbr.:Acta Anaesthesiol Scand
Publisher:Wiley
ISSN:0001-5172
ISSN (Online):1399-6576
Published Online:22 July 2020
Copyright Holders:Copyright © 2020 The Acta Anaesthesiologica Scandinavica Foundation
First Published:First published in Acta Anaesthesiologica Scandinavica 64(10):1422-1425
Publisher Policy:Reproduced in accordance with the publisher copyright policy

University Staff: Request a correction | Enlighten Editors: Update this record