Whyte, W. (1983) A multicentred investigation of clean air requirements for terminally sterilized pharmaceuticals. Journal of Parenteral Science and Technology, 37(4), pp. 138-144. (PMID:6620047)
Full text not currently available from Enlighten.
Publisher's URL: https://journal.pda.org/content/37/4/138
Abstract
Experiments were carried out in four manufacturing pharmacies to assess the effect of ventilation and airborne contamination on terminally sterilized products. Each pharmacy manufactured containers of 0.9% sodium chloride and carried out experiments in widely differing conditions of airborne cleanliness. No correlation could be demonstrated between the cleanliness of the air and the quality of the product (as established by bacterial and dust particle counts) and it was concluded that the containers and closures (especially after autoclaving) were the main source of contamination. It is suggested that complex ventilation schemes for the production of terminally sterilized products are not necessary.
Item Type: | Articles |
---|---|
Status: | Published |
Refereed: | Yes |
Glasgow Author(s) Enlighten ID: | Whyte, Dr William |
Authors: | Whyte, W. |
College/School: | College of Science and Engineering |
Journal Name: | Journal of Parenteral Science and Technology |
Publisher: | Parenteral Drug Association |
ISSN: | 0279-7976 |
University Staff: Request a correction | Enlighten Editors: Update this record