Multicenter core laboratory comparison of the instantaneous wave-free ratio and resting Pd/Pa with fractional flow reserve: the RESOLVE study

Jeremias, A. et al. (2014) Multicenter core laboratory comparison of the instantaneous wave-free ratio and resting Pd/Pa with fractional flow reserve: the RESOLVE study. Journal of the American College of Cardiology, 63(13), pp. 1253-1261. (doi: 10.1016/j.jacc.2013.09.060) (PMID:24211503)

Full text not currently available from Enlighten.

Abstract

Objectives: This study sought to examine the diagnostic accuracy of the instantaneous wave-free ratio (iFR) and resting distal coronary artery pressure/aortic pressure (Pd/Pa) with respect to hyperemic fractional flow reserve (FFR) in a core laboratory–based multicenter collaborative study. Background: FFR is an index of the severity of coronary stenosis that has been clinically validated in 3 prospective randomized trials. iFR and Pd/Pa are nonhyperemic pressure-derived indices of the severity of stenosis with discordant reports regarding their accuracy with respect to FFR. Methods: iFR, resting Pd/Pa, and FFR were measured in 1,768 patients from 15 clinical sites. An independent physiology core laboratory performed blinded off-line analysis of all raw data. The primary objectives were to determine specific iFR and Pd/Pa thresholds with ≥90% accuracy in predicting ischemic versus nonischemic FFR (on the basis of an FFR cut point of 0.80) and the proportion of patients falling beyond those thresholds. Results: Of 1,974 submitted lesions, 381 (19.3%) were excluded because of suboptimal acquisition, leaving 1,593 for final analysis. On receiver-operating characteristic analysis, the optimal iFR cut point for FFR ≤0.80 was 0.90 (C statistic: 0.81 [95% confidence interval: 0.79 to 0.83]; overall accuracy: 80.4%) and for Pd/Pa was 0.92 (C statistic: 0.82 [95% confidence interval: 0.80 to 0.84]; overall accuracy: 81.5%), with no significant difference between these resting measures. iFR and Pd/Pa had ≥90% accuracy to predict a positive or negative FFR in 64.9% (62.6% to 67.3%) and 48.3% (45.6% to 50.5%) of lesions, respectively. Conclusions: This comprehensive core laboratory analysis comparing iFR and Pd/Pa with FFR demonstrated an overall accuracy of ∼80% for both nonhyperemic indices, which can be improved to ≥90% in a subset of lesions. Clinical outcome studies are required to determine whether the use of iFR or Pd/Pa might obviate the need for hyperemia in selected patients.

Item Type:Articles
Status:Published
Refereed:Yes
Glasgow Author(s) Enlighten ID:Berry, Professor Colin and Oldroyd, Dr Keith
Authors: Jeremias, A., Maehara, A., Généreux, P., Asrress, K. N., Berry, C., De Bruyne, B., Davies, J. E., Escaned, J., Fearon, W. F., Gould, K. L., Johnson, N. P., Kirtane, A. J., Koo, B.-K., Marques, K. M., Nijjer, S., Oldroyd, K. G., Petraco, R., Piek, J. J., Pijls, N. H., Redwood, S., Siebes, M., Spaan, J. A.E., van 't Veer, M., Mintz, G. S., and Stone, G. W.
College/School:College of Medical Veterinary and Life Sciences > School of Cardiovascular & Metabolic Health
Journal Name:Journal of the American College of Cardiology
Publisher:Elsevier
ISSN:0735-1097
ISSN (Online):1558-3597

University Staff: Request a correction | Enlighten Editors: Update this record