Multicenter safety and practice for off-label diagnostic use of ferumoxytol in MRI

Nguyen, K.-L. et al. (2019) Multicenter safety and practice for off-label diagnostic use of ferumoxytol in MRI. Radiology, 293(3), pp. 554-564. (doi: 10.1148/radiol.2019190477) (PMID:31638489) (PMCID:PMC6884068)

Full text not currently available from Enlighten.

Abstract

Background Ferumoxytol is approved for use in the treatment of iron deficiency anemia, but it can serve as an alternative to gadolinium-based contrast agents. On the basis of postmarketing surveillance data, the Food and Drug Administration issued a black box warning regarding the risks of rare but serious acute hypersensitivity reactions during fast high-dose injection (510 mg iron in 17 seconds) for therapeutic use. Whereas single-center safety data for diagnostic use have been positive, multicenter data are lacking. Purpose To report multicenter safety data for off-label diagnostic ferumoxytol use. Materials and Methods The multicenter ferumoxytol MRI registry was established as an open-label nonrandomized surveillance databank without industry involvement. Each center monitored all ferumoxytol administrations, classified adverse events (AEs) using the National Cancer Institute Common Terminology Criteria for Adverse Events (grade 1-5), and assessed the relationship of AEs to ferumoxytol administration. AEs related to or possibly related to ferumoxytol injection were considered adverse reactions. The core laboratory adjudicated the AEs and classified them with the American College of Radiology (ACR) classification. Analysis of variance was used to compare vital signs. Results Between January 2003 and October 2018, 3215 patients (median age, 58 years; range, 1 day to 96 years; 1897 male patients) received 4240 ferumoxytol injections for MRI. Ferumoxytol dose ranged from 1 to 11 mg per kilogram of body weight (≤510 mg iron; rate ≤45 mg iron/sec). There were no systematic changes in vital signs after ferumoxytol administration ( > .05). No severe, life-threatening, or fatal AEs occurred. Eighty-three (1.9%) of 4240 AEs were related or possibly related to ferumoxytol infusions (75 mild [1.8%], eight moderate [0.2%]). Thirty-one AEs were classified as allergiclike reactions using ACR criteria but were consistent with minor infusion reactions observed with parenteral iron. Conclusion Diagnostic ferumoxytol use was well tolerated, associated with no serious adverse events, and implicated in few adverse reactions. Registry results indicate a positive safety profile for ferumoxytol use in MRI.

Item Type:Articles
Status:Published
Refereed:Yes
Glasgow Author(s) Enlighten ID:Stoumpos, Dr Sokratis and Radjenovic, Dr Aleksandra
Authors: Nguyen, K.-L., Yoshida, T., Kathuria-Prakash, N., Zaki, I. H., Varallyay, C. G., Semple, S. I., Saouaf, R., Rigsby, C. K., Stoumpos, S., Whitehead, K. K., Griffin, L. M., Saloner, D., Hope, M. D., Prince, M. R., Fogel, M. A., Schiebler, M. L., Roditi, G. H., Radjenovic, A., Newby, D. E., Neuwelt, E. A., Bashir, M. R., Hu, P., and Finn, J. P.
College/School:College of Medical Veterinary and Life Sciences > School of Cardiovascular & Metabolic Health
Journal Name:Radiology
Publisher:Radiological Society of North America
ISSN:1527-1315
ISSN (Online):1527-1315
Published Online:22 October 2019

University Staff: Request a correction | Enlighten Editors: Update this record