On considering magnetic saturation with maximum torque to current control in interior permanent magnet synchronous motor drives

Mademlis, C. and Agelidis, V.G. (2001) On considering magnetic saturation with maximum torque to current control in interior permanent magnet synchronous motor drives. IEEE Transactions on Energy Conversion, 16, pp. 246-252.

Full text not currently available from Enlighten.

Abstract

The influence of magnetic saturation on maximum torque to current controlled interior permanent magnet synchronous motor drives is discussed in this paper. A maximum torque to current condition that takes into account magnetic saturation and determines the optimal d-axis current is derived. For the implementation of the proposed controller, an experimental procedure is used to adjust its parameters, therefore, the knowledge of the exact model is not required. Selected experimental results are presented to verify the theoretical considerations and to confirm the high performance of the suggested controller.

Item Type:Articles
Status:Published
Refereed:Yes
Glasgow Author(s) Enlighten ID:UNSPECIFIED
Authors: Mademlis, C., and Agelidis, V.G.
College/School:College of Science and Engineering > School of Engineering > Electronics and Nanoscale Engineering
Journal Name:IEEE Transactions on Energy Conversion
Publisher:IEEE
ISSN:0885-8969
ISSN (Online):1558-0059

University Staff: Request a correction | Enlighten Editors: Update this record