External validation and calibration of IVFpredict: a national prospective cohort study of 130,960 in vitro fertilisation cycles

Smith, A. D. A. C., Tilling, K., Lawlor, D. A. and Nelson, S. M. (2015) External validation and calibration of IVFpredict: a national prospective cohort study of 130,960 in vitro fertilisation cycles. PLoS ONE, 10(4), e0121357. (doi: 10.1371/journal.pone.0121357) (PMID:25853703) (PMCID:PMC4390202)

[img]
Preview
Text
104431.pdf - Published Version
Available under License Creative Commons Attribution.

330kB

Abstract

Background: Accurately predicting the probability of a live birth after in vitro fertilisation (IVF) is important for patients, healthcare providers and policy makers. Two prediction models (Templeton and IVFpredict) have been previously developed from UK data and are widely used internationally. The more recent of these, IVFpredict, was shown to have greater predictive power in the development dataset. The aim of this study was external validation of the two models and comparison of their predictive ability.

Methods and Findings: 130,960 IVF cycles undertaken in the UK in 2008–2010 were used to validate and compare the Templeton and IVFpredict models. Discriminatory power was calculated using the area under the receiver-operator curve and calibration assessed using a calibration plot and Hosmer-Lemeshow statistic. The scaled modified Brier score, with measures of reliability and resolution, were calculated to assess overall accuracy. Both models were compared after updating for current live birth rates to ensure that the average observed and predicted live birth rates were equal. The discriminative power of both methods was comparable: the area under the receiver-operator curve was 0.628 (95% confidence interval (CI): 0.625–0.631) for IVFpredict and 0.616 (95% CI: 0.613–0.620) for the Templeton model. IVFpredict had markedly better calibration and higher diagnostic accuracy, with calibration plot intercept of 0.040 (95% CI: 0.017–0.063) and slope of 0.932 (95% CI: 0.839–1.025) compared with 0.080 (95% CI: 0.044–0.117) and 1.419 (95% CI: 1.149–1.690) for the Templeton model. Both models underestimated the live birth rate, but this was particularly marked in the Templeton model. Updating the models to reflect improvements in live birth rates since the models were developed enhanced their performance, but IVFpredict remained superior.

Conclusion: External validation in a large population cohort confirms IVFpredict has superior discrimination and calibration for informing patients, clinicians and healthcare policy makers of the probability of live birth following IVF.

Item Type:Articles
Status:Published
Refereed:Yes
Glasgow Author(s) Enlighten ID:Nelson, Professor Scott
Authors: Smith, A. D. A. C., Tilling, K., Lawlor, D. A., and Nelson, S. M.
College/School:College of Medical Veterinary and Life Sciences > School of Medicine, Dentistry & Nursing
Journal Name:PLoS ONE
Publisher:Public Library of Science
ISSN:1932-6203
ISSN (Online):1932-6203
Copyright Holders:Copyright © 2015 The Authors
First Published:First published in PLoS ONE 10(4):e0121357
Publisher Policy:Reproduced under a Creative Commons License

University Staff: Request a correction | Enlighten Editors: Update this record

Project CodeAward NoProject NamePrincipal InvestigatorFunder's NameFunder RefLead Dept
557181Do measures in cord blood predict long term offspring phenotype?Scott NelsonWellcome Trust (WELLCOME)094311/Z/10/ZMVLS MED - REPRODUCTIVE & MATERNAL MED