Absorption measurements of periodically poled potassium titanyl phosphate (PPKTP) at 775 nm and 1550 nm

Steinlechner, J., Ast, S., Krueger, C., Pal Singh, A., Eberle, T., Haendchen, V. and Schnabel, R. (2013) Absorption measurements of periodically poled potassium titanyl phosphate (PPKTP) at 775 nm and 1550 nm. Sensors, 13(1), pp. 565-573. (doi: 10.3390/s130100565)

[img]
Preview
Text
99155.pdf - Published Version
Available under License Creative Commons Attribution.

317kB

Abstract

The efficient generation of second-harmonic light and squeezed light requires non-linear crystals that have low absorption at the fundamental and harmonic wavelengths. In this work the photo-thermal self-phase modulation technique is exploited to measure the absorption coefficient of periodically poled potassium titanyl phosphate (PPKTP) at 1,550 nm and 775 nm. Themeasurement results are (84±40) ppm/cm and (127±24) ppm/cm, respectively. We conclude that the performance of state-of-the-art frequency doubling and squeezed light generation in PPKTP is not limited by absorption.

Item Type:Articles
Status:Published
Refereed:Yes
Glasgow Author(s) Enlighten ID:Steinlechner, Dr Jessica
Authors: Steinlechner, J., Ast, S., Krueger, C., Pal Singh, A., Eberle, T., Haendchen, V., and Schnabel, R.
Subjects:Q Science > QC Physics
College/School:College of Science and Engineering > School of Physics and Astronomy
Journal Name:Sensors
Publisher:MDPI
ISSN:1424-8220
ISSN (Online):1424-8220
Copyright Holders:Copyright © 2014 The Authors
First Published:First published in Sensors 13(1):565-573
Publisher Policy:Reproduced under a Creative Commons License

University Staff: Request a correction | Enlighten Editors: Update this record