Blending polysaccharides with biodegradable polymers. II. Structure and biological response of chitosan/polycaprolactone blends

García Cruz, D.M., Coutinho, D.F., Costa Martinez, E., Mano, J.F., Gómez Ribelles, J.L. and Salmerón-Sánchez, M. (2008) Blending polysaccharides with biodegradable polymers. II. Structure and biological response of chitosan/polycaprolactone blends. Journal of Biomedical Materials Research Part B: Applied Biomaterials, 87B(2), pp. 544-554. (doi: 10.1002/jbm.b.31142)

Full text not currently available from Enlighten.

Abstract

Blends of polycaprolactone (PCL) and chitosan (CHT) were prepared by casting from the mixture of solutions of both components in suitable solvents. PCL, and CHT, form phase separated blends with improved mechanical properties and increased water sorption ability with respect to pure PCL. The morphology of the system was investigated by scanning electron microscopy (SEM), atomic force microscopy (AFM) and confocal microscopy. Dispersed domains of CHT in the semicrystalline PCL matrix were found in samples with less than 20% CHT but cocontinuous phase morphologies are found in blends with 20% or more CHT. This feature was corroborated by the temperature dependence of the elastic modulus measured by dynamic mechanical properties as a function of temperature. It was observed that for those blends above 20 wt% CHT, the mechanical stability of the system was kept even after melting of the PCL phase. Primary human chondrocytes were cultured on the different substrates. Cell morphology was studied by SEM and the viability and proliferation was investigated by the colorimetric MTT assay. Different protein conformations were found by AFM on CHT and PCL samples which were related to the biological performance of the substrates. Hydrophilicty of the material is not directly related to the biological response and the sample with 20 wt% CHT shows better results than the other blends with respect to chondrocyte viability and proliferation. However, the results obtained in the blends are worse than in pure PCL. It seems to be correlated with the surface energy of the different blends rather than hydrophilicity.

Item Type:Articles
Status:Published
Refereed:Yes
Glasgow Author(s) Enlighten ID:Salmeron-Sanchez, Professor Manuel
Authors: García Cruz, D.M., Coutinho, D.F., Costa Martinez, E., Mano, J.F., Gómez Ribelles, J.L., and Salmerón-Sánchez, M.
College/School:College of Science and Engineering > School of Engineering > Biomedical Engineering
Journal Name:Journal of Biomedical Materials Research Part B: Applied Biomaterials
ISSN:1552-4973
ISSN (Online):1552-4981
Published Online:10 June 2008

University Staff: Request a correction | Enlighten Editors: Update this record