Diffusion-weighted imaging in uterine artery embolisation: do findings correlate with contrast enhancement and volume reduction?

Ananthakrishnan, G., Macnaught, G., Hinksman, L., Gilmour, H., Forbes, K.P. and Moss, J.P. (2012) Diffusion-weighted imaging in uterine artery embolisation: do findings correlate with contrast enhancement and volume reduction? British Journal of Radiology, 85(1019), e1046-e1050. (doi: 10.1259/bjr/91540172)

Full text not currently available from Enlighten.

Abstract

Objectives The objective of this study was to determine the role of diffusion-weighted imaging (DWI) in uterine artery embolisation (UAE), and to assess the apparent diffusion coefficient (ADC) of the dominant fibroid and its relationship to contrast enhancement and fibroid volume reduction. Methods We carried out a retrospective study of 15 patients who underwent UAE. Calculations were performed at baseline and 6 months post-embolisation. Fibroid ADC (expressed in 10−3 mm2 s−1) was calculated using b=0 and b=1000 DWI values. Fibroid enhancement was compared with background myometrium by measuring signal-difference-to-noise ratio (SDNR). Fibroid volume was calculated using a prolate ellipse formula. Results There was a significant reduction (p<0.001) in fibroid ADC at 6 months (0.48; standard deviation, SD=0.26) as compared with baseline (1.01; SD=0.39). No significant change (p=0.07) was identified in 6-month myometrial ADC (1.09; SD=0.28) as compared with baseline (1.24; SD=0.20). Moderately strong and significant positive correlation was identified between baseline ADC and 6-month percentage volume reduction of the fibroid (correlation=0.66, p=0.007). No correlation was identified between SDNR and ADC at baseline or 6 months (r=0.01, p=0.97 and r=−0.13, p=0.64, respectively) or SDNR and percentage volume reduction at 6 months (correlation r=0.18, p=0.51). Conclusion Baseline ADC of dominant fibroids shows a moderately strong correlation with subsequent volume reduction at 6 months following UAE. No correlation was identified between ADC values and contrast enhancement on the baseline or 6-month scans. Further prospective evaluation is needed before DWI can be utilised in clinical practice. Advances in knowledge DWI imaging may provide additional information about UAE and possibly help to predict uterine volume reduction.

Item Type:Articles
Status:Published
Refereed:Yes
Glasgow Author(s) Enlighten ID:Gilmour, Mr Harper and Moss, Professor Jonathan and Forbes, Dr Kirsten
Authors: Ananthakrishnan, G., Macnaught, G., Hinksman, L., Gilmour, H., Forbes, K.P., and Moss, J.P.
College/School:College of Medical Veterinary and Life Sciences > School of Medicine, Dentistry & Nursing
College of Science and Engineering > School of Mathematics and Statistics
Journal Name:British Journal of Radiology
ISSN:0007-1285
Published Online:16 August 2012

University Staff: Request a correction | Enlighten Editors: Update this record