‘Time critical’ rapid amputation using fire service hydraulic cutting equipment

McNicholas, M.J., Robinson, S.J., Polyzois, I., Dunbar, I., Payne, A.P. and Forrest, M. (2011) ‘Time critical’ rapid amputation using fire service hydraulic cutting equipment. Injury, 42(11), pp. 1333-1335. (doi: 10.1016/j.injury.2011.05.002)

Full text not currently available from Enlighten.

Publisher's URL: http://dx.doi.org/10.1016/j.injury.2011.05.002

Abstract

<p><b>Introduction:</b> Entrapped trauma victims require extrication, which, on rare occasions, may involve amputation of a limb. Standard extrication techniques sometimes fail or may be impossible, leading to the death of the entrapped victim. We propose that the use of fire service hydraulic cutting equipment can be used effectively to urgently amputate a limb, where conventional techniques are unusable.</p> <p><b>Method:</b> The study aims to determine: (i) the potential use of this equipment to achieve expeditious life-saving amputations and (ii) the effect the fire service hydraulic cutting equipment has on the bony and surrounding soft tissues. Initially a porcine limb was used followed by fresh-frozen cadaveric lower limbs. We recorded the time, number of cuts, proximal fracture propagation and quality of bone cut when performing amputations at five levels.</p> <p><b>Results:</b> The experiment confirms that faster guillotine amputations in human cadaveric lower limb specimens can be achieved by using fire service hydraulic cutting equipment. Overall, the average time to complete an amputation in these ideal experimental circumstances at all five levels was quicker using the hydraulic cutting equipment. Either one or two cutting actions were required to achieve the amputation using fire service hydraulic cutting equipment. The degree and proximal extent of the comminution were greater using the fire service hydraulic cutting equipment.</p> <p><b>Conclusion:</b> If circumstances and time constrains allow, a conventional amputation technique carried out by a trained medical practitioner would be preferable to the use of the fire service hydraulic cutting equipment. However, we feel that this technique could be used to perform emergent amputation under trained medical supervision, if it is felt that a standard amputation technique would take too long or the environment is too restrictive to perform a standard amputation safely.</p>

Item Type:Articles
Status:Published
Refereed:Yes
Glasgow Author(s) Enlighten ID:Payne, Professor Anthony
Authors: McNicholas, M.J., Robinson, S.J., Polyzois, I., Dunbar, I., Payne, A.P., and Forrest, M.
College/School:College of Medical Veterinary and Life Sciences > School of Life Sciences
Journal Name:Injury
ISSN:0020-1383
ISSN (Online):1879-0267
Published Online:01 November 2011

University Staff: Request a correction | Enlighten Editors: Update this record