Computed tomography and magnetic resonance perfusion imaging in ischemic stroke: definitions and thresholds

Dani, K.A., Thomas, R.G.R., Chappell, F.M., Shuler, K., MacLeod, M.J., Muir, K.W. and Wardlaw, J.M. (2011) Computed tomography and magnetic resonance perfusion imaging in ischemic stroke: definitions and thresholds. Annals of Neurology, 70(3), pp. 384-401. (doi: 10.1002/ana.22500)

Full text not currently available from Enlighten.

Publisher's URL: http://dx.doi.org/10.1002/ana.22500

Abstract

Objective: Cerebral perfusion imaging with computed tomography (CT) or magnetic resonance (MR) is widely available. The optimum perfusion values to identify tissue at risk of infarction in acute stroke are unclear. We systematically reviewed CT and MR perfusion imaging in acute ischemic stroke. Methods: We searched for papers on MR or CT perfusion performed <24 hours after stroke that assessed perfusion thresholds, mean perfusion lesion values, or lesion volumes. We extracted definitions and perfusion values. We compared definitions and evaluated perfusion thresholds for "nonviable''/" at risk'' and "at risk''/'' not at risk tissue'' thresholds. Results: Among 7,152 papers, 69 met inclusion criteria for analysis of definitions (49 MR and 20 CT), 21 MR (n = 551), and 10 CT (n = 266) papers, median sample size 22, provided thresholds. We found multiple definitions for tissue states, eg, tissue at risk, 18; nonviable tissue, 12; 16, no definition. Perfusion parameters varied widely; eg, 9 different MR, 6 different CT parameters for the "at risk''/'' not at risk threshold.'' Median threshold values varied up to 4-fold, eg, for the "at risk''/'' not at risk threshold,'' median cerebral blood flow ranged from 18 to 37ml/100g/min; mean transit time from 1.8 to 8.3 seconds relative to the contralateral side. The influence of reperfusion and duration of ischemia could not be assessed. Interpretation: CT and MR perfusion imaging viability thresholds in stroke are derived from small numbers of patients, variable perfusion analysis methods and definitions of tissue states. Greater consistency of methods would help determine reliable perfusion viability values for wider clinical use of perfusion imaging.

Item Type:Articles
Status:Published
Refereed:Yes
Glasgow Author(s) Enlighten ID:Muir, Professor Keith and Dani, Dr Krishna
Authors: Dani, K.A., Thomas, R.G.R., Chappell, F.M., Shuler, K., MacLeod, M.J., Muir, K.W., and Wardlaw, J.M.
College/School:College of Medical Veterinary and Life Sciences > School of Psychology & Neuroscience
Journal Name:Annals of Neurology
Publisher:John Wiley and Sons, Inc.
ISSN:0364-5134

University Staff: Request a correction | Enlighten Editors: Update this record