Dynamic multi-objective optimization applied to a solar-geothermal multi-generation system for hydrogen production, desalination, and energy storage

Sohani, A., Delfani, F., Hosseini, M., Sayyaadi, H., Karimi, N. , Li, L. K.B. and Doranehgard, M. H. (2022) Dynamic multi-objective optimization applied to a solar-geothermal multi-generation system for hydrogen production, desalination, and energy storage. International Journal of Hydrogen Energy, 47(74), pp. 31730-31741. (doi: 10.1016/j.ijhydene.2022.03.253)

[img] Text
269306.pdf - Accepted Version
Available under License Creative Commons Attribution Non-commercial No Derivatives.

1MB

Abstract

The design of optimal energy systems is vital to achieving global environmental and economic targets. In the design of solar-geothermal multi-generation systems, most previous investigations have relied on the static multi-objective optimization approach (SMOA), which may leave considerable room for improvement under certain conditions. In this numerical study, the optimal condition at which to operate a solar-geothermal multi-generation system – which can simultaneously produce hydrogen, fresh water, electricity, and heat, along with storing energy − is determined via a dynamic multi-objective optimization approach (DMOA). Optimization is performed using a combination of NSGA-II and TOPSIS, and the results are benchmarked against those of SMOA. The decision variables include the solar area, geothermal water extraction mass flow, and hydrogen storage pressure. The objective functions include the production of electricity, heat, hydrogen, and fresh water, along with the exergy and energy efficiencies and the payback period. It is found that when compared with SMOA, DMOA can significantly improve all the objective functions. The annual production of electricity, heat, hydrogen, and fresh water increases by 14.4, 16.1, 13.5, and 14.3%, respectively, while the average annual exergy and energy efficiencies increase by 5.2 and 3.0%, respectively. The use of DMOA also reduces the payback period from 5.56 to 4.43 years, with a 4.4% reduction in hydrogen storage pressure. This shows that compared with a static approach such as SMOA, DMOA can improve the exergy and energy efficiencies, economic viability, and safety of a solar-geothermal multi-generation system.

Item Type:Articles
Status:Published
Refereed:Yes
Glasgow Author(s) Enlighten ID:Karimi, Dr Nader
Authors: Sohani, A., Delfani, F., Hosseini, M., Sayyaadi, H., Karimi, N., Li, L. K.B., and Doranehgard, M. H.
College/School:College of Science and Engineering > School of Engineering
Journal Name:International Journal of Hydrogen Energy
Publisher:Elsevier
ISSN:03603199
ISSN (Online):1879-3487
Published Online:15 April 2022
Copyright Holders:Copyright © 2022 Elsevier
First Published:First publishe47(74): 31730-31741
Publisher Policy:Reproduced in accordance with the copyright policy of the publisher

University Staff: Request a correction | Enlighten Editors: Update this record