Clinical magnetic resonance image quality of the equine foot is significantly influenced by acquisition system

Byrne, C. A. , Marshall, J. F. and Voute, L. C. (2021) Clinical magnetic resonance image quality of the equine foot is significantly influenced by acquisition system. Equine Veterinary Journal, 53(3), pp. 469-480. (doi: 10.1111/evj.13330) (PMID:32767582)

[img] Text
222836.pdf - Published Version
Available under License Creative Commons Attribution.

899kB

Abstract

Background: Investigation of image quality in clinical equine magnetic resonance (MR) imaging may optimise diagnostic value. Objectives: To assess the influence of field strength and anaesthesia on image quality in MR imaging of the equine foot in a clinical context. Study design: Analytical clinical study. Methods: Fifteen equine foot studies (five studies per system) were randomly selected from the clinical databases of three MR imaging systems: low‐field standing (LF St), low‐field anaesthetised (LF GA) and high‐field anaesthetised (HF GA). Ten experienced observers graded image quality for entire studies and seven clinically important anatomical structures within the foot (briefly, grade 1: textbook quality, grade 2: high diagnostic quality, grade 3: satisfactory diagnostic quality, grade 4: non‐diagnostic). Statistical analysis assessed the effect of anaesthesia and field strength using a combination of the Pearson chi‐square test or Fisher’s exact test and Mann‐Whitney test. Results: There was no difference in the proportion of entire studies of diagnostic quality between LF St (90%, 95%CI 78‐97%) and LF GA (88%, 76‐95%, p = 0.7). No differences were evident in the proportion of diagnostic studies or median image quality gradings between LF St and LF GA when assessing individual anatomical structures (both groups all median grades=3). There was a statistically significant difference in the proportion of entire studies of diagnostic quality between LF GA and HF GA (100%, 95% CI lower bound 94%, p = 0.03). There were statistically significant differences in median image quality gradings between LF GA (all median grades=3) and HF GA (median grades=1 (5/7 structures) or 2 (2/7 structures) for all individual anatomical structures (all P<0.001). The reasons reported for reduced image quality differed between systems. Main limitations: Randomised selection of cases from clinical databases. Individual observer preferences may influence image quality assessment. Conclusions: Field strength is a more important influencer of image quality than anaesthesia for magnetic resonance imaging of the equine foot in clinical patients.

Item Type:Articles
Additional Information:The study was funded by a Horserace Betting Levy Board small project grant (reference number: SPrj033).
Status:Published
Refereed:Yes
Glasgow Author(s) Enlighten ID:Byrne, Mr Christian and Voute, Dr Lance and Marshall, Dr John
Authors: Byrne, C. A., Marshall, J. F., and Voute, L. C.
College/School:College of Medical Veterinary and Life Sciences
College of Medical Veterinary and Life Sciences > School of Biodiversity, One Health & Veterinary Medicine
Journal Name:Equine Veterinary Journal
Publisher:Wiley
ISSN:2042-3306
ISSN (Online):2042-3306
Published Online:07 August 2020
Copyright Holders:Copyright © 2020 The Authors.
First Published:First published in Equine Veterinary Journal 53(3): 469-480
Publisher Policy:Reproduced under a Creative Commons license

University Staff: Request a correction | Enlighten Editors: Update this record