Prospective motion correction in 2D multishot MRI using EPI navigators and multislice-to-volume image registration

Hoinkiss, D. C. and Porter, D. A. (2017) Prospective motion correction in 2D multishot MRI using EPI navigators and multislice-to-volume image registration. Magnetic Resonance in Medicine, 78(6), pp. 2127-2135. (doi: 10.1002/mrm.26951) (PMID:28983957)

Full text not currently available from Enlighten.

Abstract

Purpose: Prospective motion correction reduces artifacts in MRI by correcting for subject motion in real time, but techniques are limited for multishot 2‐dimensional (2D) sequences. This study addresses this limitation by using 2D echo‐planar imaging (EPI) slice navigator acquisitions together with a multislice‐to‐volume image registration. Methods: The 2D‐EPI navigators were integrated into 2D imaging sequences to allow a rapid, real‐time motion correction based on the registration of three navigator slices to a reference volume. A dedicated slice‐iteration scheme was used to limit mutual spin‐saturation effects between navigator and image data. The method was evaluated using T2‐weighted spin echo and multishot rapid acquisition with relaxation enhancement (RARE) sequences, and its motion‐correction capabilities were compared with those of periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER). Validation was performed in vivo using a well‐defined motion protocol. Results: Data acquired during subject motion showed residual motion parameters within ±0.5 mm and ±0.5°, and demonstrated a substantial improvement in image quality compared with uncorrected scans. In a comparison to PROPELLER, the proposed technique preserved a higher level of anatomical detail in the presence of subject motion. Conclusions: EPI‐navigator‐based prospective motion correction using multislice‐to‐volume image registration can substantially reduce image artifacts, while minimizing spin‐saturation effects. The method can be adapted for use in other 2D MRI sequences and promises to improve image quality in routine clinical examinations.

Item Type:Articles
Status:Published
Refereed:Yes
Glasgow Author(s) Enlighten ID:Porter, Professor David
Authors: Hoinkiss, D. C., and Porter, D. A.
College/School:College of Medical Veterinary and Life Sciences > School of Psychology & Neuroscience
Journal Name:Magnetic Resonance in Medicine
Publisher:Wiley
ISSN:0740-3194
ISSN (Online):1522-2594
Published Online:05 October 2017

University Staff: Request a correction | Enlighten Editors: Update this record