Non-destructive Testing of Fuel Tanks Using Long-range Ultrasonics

Mazeika, L., Kazys, R., Raisutis, R., Demcenko, A. , Sliteris, R. and Cantore, C. (2008) Non-destructive Testing of Fuel Tanks Using Long-range Ultrasonics. In: Emerging Technologies in ETNDT . 4th International Conference on Emerging Technologies in Non-Destructive Testing, ETNDT 4, Stuttgart, Germany, 2-4 April 2007,

Full text not currently available from Enlighten.

Abstract

The new ultrasonic technique based on application of long range guided waves is proposed for detection of the defects in a storage tank floor. The technique needs access only to the outer edge of the tank floor and do not require emptying and cleaning of the tank. The propagation of the guided waves in the tank floor has been carried out using simulation and experimental verification. The results obtained on the reduced size tank and results of in situ experiments are presented.

Item Type:Conference Proceedings
Status:Published
Refereed:Yes
Glasgow Author(s) Enlighten ID:Demcenko, Dr Andriejus
Authors: Mazeika, L., Kazys, R., Raisutis, R., Demcenko, A., Sliteris, R., and Cantore, C.
College/School:College of Science and Engineering > School of Engineering > Biomedical Engineering

University Staff: Request a correction | Enlighten Editors: Update this record