Quantitative myocardial perfusion imaging versus visual analysis in diagnosing myocardial ischemia: a CE-MARC substudy

Biglands, J. D., Ibraheem, M., Magee, D. R., Radjenovic, A. , Plein, S. and Greenwood, J. P. (2018) Quantitative myocardial perfusion imaging versus visual analysis in diagnosing myocardial ischemia: a CE-MARC substudy. JACC: Cardiovascular Imaging, 11(5), pp. 711-718. (doi: 10.1016/j.jcmg.2018.02.019) (PMID:29747847)

[img]
Preview
Text
162682.pdf - Accepted Version
Available under License Creative Commons Attribution Non-commercial No Derivatives.

445kB

Abstract

Objectives: This study sought to compare the diagnostic accuracy of visual and quantitative analyses of myocardial perfusion cardiovascular magnetic resonance against a reference standard of quantitative coronary angiography. Background: Visual analysis of perfusion cardiovascular magnetic resonance studies for assessing myocardial perfusion has been shown to have high diagnostic accuracy for coronary artery disease. However, only a few small studies have assessed the diagnostic accuracy of quantitative myocardial perfusion. Methods: This retrospective study included 128 patients randomly selected from the CE-MARC (Clinical Evaluation of Magnetic Resonance Imaging in Coronary Heart Disease) study population such that the distribution of risk factors and disease status was proportionate to the full population. Visual analysis results of cardiovascular magnetic resonance perfusion images, by consensus of 2 expert readers, were taken from the original study reports. Quantitative myocardial blood flow estimates were obtained using Fermi-constrained deconvolution. The reference standard for myocardial ischemia was a quantitative coronary x-ray angiogram stenosis severity of ≥70% diameter in any coronary artery of >2 mm diameter, or ≥50% in the left main stem. Diagnostic performance was calculated using receiver-operating characteristic curve analysis. Results: The area under the curve for visual analysis was 0.88 (95% confidence interval: 0.81 to 0.95) with a sensitivity of 81.0% (95% confidence interval: 69.1% to 92.8%) and specificity of 86.0% (95% confidence interval: 78.7% to 93.4%). For quantitative stress myocardial blood flow the area under the curve was 0.89 (95% confidence interval: 0.83 to 0.96) with a sensitivity of 87.5% (95% confidence interval: 77.3% to 97.7%) and specificity of 84.5% (95% confidence interval: 76.8% to 92.3%). There was no statistically significant difference between the diagnostic performance of quantitative and visual analyses (p = 0.72). Incorporating rest myocardial blood flow values to generate a myocardial perfusion reserve did not significantly increase the quantitative analysis area under the curve (p = 0.79). Conclusions: Quantitative perfusion has a high diagnostic accuracy for detecting coronary artery disease but is not superior to visual analysis. The incorporation of rest perfusion imaging does not improve diagnostic accuracy in quantitative perfusion analysis.

Item Type:Articles
Keywords:Cardiovascular magnetic resonance, diagnostic accuracy, myocardial ischemia, quantitative myocardial perfusion.
Status:Published
Refereed:Yes
Glasgow Author(s) Enlighten ID:Radjenovic, Dr Aleksandra
Authors: Biglands, J. D., Ibraheem, M., Magee, D. R., Radjenovic, A., Plein, S., and Greenwood, J. P.
College/School:College of Medical Veterinary and Life Sciences > School of Cardiovascular & Metabolic Health
Journal Name:JACC: Cardiovascular Imaging
Publisher:Elsevier
ISSN:1936-878X
ISSN (Online):1876-7591
Published Online:07 May 2018
Copyright Holders:Copyright © 2018 American College of Cardiology Foundation
First Published:First published in JACC: Cardiovascular Imaging 11(5): 711-718