Cantone, M. C., Ginjaume, M., Miljanic, S., Martin, C. J., Akahane, K., Mpete, L., Michelin, S. C., Flannery, C. M., Dauer, L. T. and Balter, S. (2017) Report of IRPA task group on the impact of the eye lens dose limits. Journal of Radiological Protection, 37(2), pp. 527-550. (doi: 10.1088/1361-6498/aa604b)
|
Text
146216.pdf - Published Version Available under License Creative Commons Attribution. 342kB |
Abstract
In 2012 IRPA established a task group (TG) to identify key issues in the implementation of the revised eye lens dose limit. The TG reported its conclusions in 2013. In January 2015, IRPA asked the TG to review progress with the implementation of the recommendations from the early report and to collate current practitioner experience. This report presents the results of a survey on the view of the IRPA professionals on the new limit to the lens of the eye and on the wider issue of tissue reactions. Recommendations derived from the survey are presented. This report was approved by IRPA Executive Council on 31 January 2017.
Item Type: | Articles |
---|---|
Status: | Published |
Refereed: | Yes |
Glasgow Author(s) Enlighten ID: | Martin, Dr Colin |
Authors: | Cantone, M. C., Ginjaume, M., Miljanic, S., Martin, C. J., Akahane, K., Mpete, L., Michelin, S. C., Flannery, C. M., Dauer, L. T., and Balter, S. |
College/School: | College of Medical Veterinary and Life Sciences > School of Medicine, Dentistry & Nursing |
Journal Name: | Journal of Radiological Protection |
Publisher: | IOP Publishing |
ISSN: | 0952-4746 |
ISSN (Online): | 1361-6498 |
Published Online: | 06 June 2017 |
Copyright Holders: | Copyright © 2017 The Authors |
First Published: | First published in Journal of Radiological Protection 37(2):527-550 |
Publisher Policy: | Reproduced under a Creative Commons License |