Computer-assisted planning and navigation improves cutting accuracy during simulated bone tumor surgery of the pelvis

Cartiaux, O., Banse, X., Paul, L., Francq, B. G., Aubin, C.-É. and Docquier, P.-L. (2013) Computer-assisted planning and navigation improves cutting accuracy during simulated bone tumor surgery of the pelvis. Computer Aided Surgery, 18(1-2), pp. 19-26. (doi: 10.3109/10929088.2012.744096) (PMID:23176154)

Full text not currently available from Enlighten.

Abstract

Background: Resection of bone tumors within the pelvis requires good cutting accuracy to achieve satisfactory safe margins. Manually controlled bone cutting can result in serious errors, especially due to the complex three-dimensional geometry, limited visibility, and restricted working space of the pelvic bone. This experimental study investigated cutting accuracy during navigated and non-navigated simulated bone tumor cutting in the pelvis. Methods: A periacetabular tumor resection was simulated using a pelvic bone model. Twenty-three operators (10 senior and 13 junior surgeons) were asked to perform the tumor cutting, initially according to a freehand procedure and later with the aid of a navigation system. Before cutting, each operator used preoperative planning software to define four target planes around the tumor with a 10-mm desired safe margin. After cutting, the location and flatness of the cut planes were measured, as well as the achieved surgical margins and the time required for each cutting procedure. Results: The location of the cut planes with respect to the target planes was significantly improved by using the navigated cutting procedure, averaging 2.8 mm as compared to 11.2 mm for the freehand cutting procedure (p < 0.001). There was no intralesional tumor cutting when using the navigation system. The maximum difference between the achieved margins and the 10-mm desired safe margin was 6.5 mm with the navigated cutting process (compared to 13 mm with the freehand cutting process). Conclusions: Cutting accuracy during simulated bone cuts of the pelvis can be significantly improved by using a freehand process assisted by a navigation system. When fully validated with complementary in vivo studies, the planning and navigation-guided technologies that have been developed for the present study may improve bone cutting accuracy during pelvic tumor resection by providing clinically acceptable margins.

Item Type:Articles
Status:Published
Refereed:Yes
Glasgow Author(s) Enlighten ID:Francq, Dr Bernard
Authors: Cartiaux, O., Banse, X., Paul, L., Francq, B. G., Aubin, C.-É., and Docquier, P.-L.
College/School:College of Medical Veterinary and Life Sciences > School of Health & Wellbeing > Robertson Centre
Journal Name:Computer Aided Surgery
Publisher:Informa UK Ltd.
ISSN:1092-9088
ISSN (Online):1097-0150

University Staff: Request a correction | Enlighten Editors: Update this record