A CubeSat for calibrating ground-based and sub-orbital millimeter-wave polarimeters (CalSat)

Johnson, B. r., Vourch, C. J., Drysdale, T. D., Kalman, A., Fujikawa, S., Keating, B. and Kaufman, J. (2015) A CubeSat for calibrating ground-based and sub-orbital millimeter-wave polarimeters (CalSat). arXiv, (Unpublished)

Full text not currently available from Enlighten.

Publisher's URL: http://arxiv.org/abs/1505.07033

Abstract

We describe a low-cost, open-access, CubeSat-based calibration instrument that is designed to support ground-based and sub-orbital experiments searching for various polarization signals in the cosmic microwave background (CMB). All modern CMB polarization experiments require a robust calibration program that will allow the effects of instrument-induced signals to be mitigated during data analysis. A bright, compact, and linearly polarized astrophysical source with polarization properties known to adequate precision does not exist. Therefore, we designed a space-based millimeter-wave calibration instrument, called CalSat, to serve as an open-access calibrator, and this paper describes the results of our design study. The calibration source on board CalSat is composed of five "tones" with one each at 47.1, 80.0, 140, 249 and 309 GHz. The five tones we chose are well matched to (i) the observation windows in the atmospheric transmittance spectra, (ii) the spectral bands commonly used in polarimeters by the CMB community, and (iii) The Amateur Satellite Service bands in the Table of Frequency Allocations used by the Federal Communications Commission. CalSat would be placed in a polar orbit allowing visibility from observatories in the Northern Hemisphere, such as Mauna Kea in Hawaii and Summit Station in Greenland, and the Southern Hemisphere, such as the Atacama Desert in Chile and the South Pole. CalSat also would be observable by balloon-borne instruments launched from a range of locations around the world. This global visibility makes CalSat the only source that can be observed by all terrestrial and sub-orbital observatories, thereby providing a universal standard that permits comparison between experiments using appreciably different measurement approaches.

Item Type:Articles
Status:Unpublished
Refereed:No
Glasgow Author(s) Enlighten ID:Drysdale, Dr Timothy
Authors: Johnson, B. r., Vourch, C. J., Drysdale, T. D., Kalman, A., Fujikawa, S., Keating, B., and Kaufman, J.
College/School:College of Science and Engineering > School of Engineering > Electronics and Nanoscale Engineering
Journal Name:arXiv
Publisher:arXiv

University Staff: Request a correction | Enlighten Editors: Update this record