Component rotational alignment in unexplained painful primary total knee arthroplasty

Bell, S. W., Young, P., Drury, C., Smith, J., Anthony, I., Jones, B., Blyth, M. and McLean, A. (2014) Component rotational alignment in unexplained painful primary total knee arthroplasty. Knee, 21(1), pp. 272-277. (doi: 10.1016/j.knee.2012.09.011) (PMID:23140906)

Full text not currently available from Enlighten.

Abstract

Background Rotational malalignment of the components in total knee arthroplasty (TKA) can be a factor in poor outcomes but has yet to be defined. This study compares the rotational alignment of components in a cohort of 56 patients with unexplained pain following total knee arthroplasty with a matched control cohort of 56 patients with cemented Nex Gen Legacy posterior stabilised (LPS) flex fixed bearing TKA between March 2006 and May 2010. The aim of the study was to define an acceptable limit of rotation in total knee replacement.<p></p> Methods Rotational alignment was calculated using the Berger protocol with post operative computerised tomography scanning. The alignment parameters measured were tibial and femoral component rotations and the combined component rotations and the component rotational mismatch.<p></p> Results The two cohorts were demographically matched. Excessive internal rotation of the components was defined using the tenth percentile of rotations in the control cohort. Values of excessive internal rotation were 5.8° of the tibial component, 3.9° of the femoral component, 8.7° of combined rotation and 5.6° of the component mismatch. No significant difference was identified in excessive external rotation in any of the parameters. A significant difference in the mean rotations between the two cohorts was identified with internal rotation of the components in the painful cohort and external rotation on the control cohort.<p></p> Conclusions We identified internal rotation malalignment of the tibial (p = 0.0003) and femoral (p = 0.014) components individually as well as the combined component rotation (p = 0.0003) and component rotation mismatch (p = 0.0001) to be a factor in pain following TKA. External rotation of any of the component parameters was not identified to be a factor in painful TKA. This study adds to the understanding of rotational alignment in TKA and suggests limits of internal rotation alignment associated with painful Nex Gen Legacy posterior stabilised (LPS) flex fixed bearing TKA.<p></p>

Item Type:Articles
Status:Published
Refereed:Yes
Glasgow Author(s) Enlighten ID:Jones, Mr Bryn
Authors: Bell, S. W., Young, P., Drury, C., Smith, J., Anthony, I., Jones, B., Blyth, M., and McLean, A.
College/School:College of Medical Veterinary and Life Sciences > School of Medicine, Dentistry & Nursing
Journal Name:Knee
Publisher:Elsevier
ISSN:0968-0160
ISSN (Online):1873-5800

University Staff: Request a correction | Enlighten Editors: Update this record